Esprit 748+ 25
6.11 Report Zone Restore Options
Feature Select Programming
D
Address 088; key [BYP]
Default: Zone Restore Codes Transmit on Bell Cut-Off
With the [
BYP] key “Off”, the report codes programmed at addresses 424-447 (see Restore Codes in section 6.6.4) will only
transmit if the zone has returned to normal after bell cut-off (see section 8.11). With the [BYP] key “On”, the codes will transmit as
soon as the zone returns to normal (zone closure).
Key [
BYP] "Off": Report on Bell Cut-Off
Key [BYP] "On": Report on zone closure
[
ENTER] + Installer Code + [10] [8] [8] + [BYP] On/Off + [ENTER]
6.12 Report Code Disarming Options
Feature Select Programming
D
Address 088; key [TRBL]
Default: Disarming Codes Transmit on User Disarming
With the [
TRBL] key "OFF", the Disarming Codes programmed at addresses 350-399 (see in section 6.6.2) will transmit whenever
a User disarms the system. With the [TRBL] key "ON", the control panel will transmit these codes when a User disarms a system
in alarm.
Key [
TRBL] "Off": Always Report Disarm
Key [
TRBL] "On": Report Disarm Only After Alarm
[ENTER] + Installer Code + [10] [8] [8] + [TRBL] On/Off + [ENTER]